J. Anim Sci.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Qiao, Y.
Right arrow Articles by van Kempen, T. A. T. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Qiao, Y.
Right arrow Articles by van Kempen, T. A. T. G.
J. Anim. Sci. 2004. 82:2596-2600
© 2004 American Society of Animal Science


ANIMAL NUTRITION

Technical note: Comparison of Raman, mid, and near infrared spectroscopy for predicting the amino acid content in animal meals1,2

Y. Qiao3 and T. A. T. G. van Kempen4

Department of Animal Science, North Carolina State University, Raleigh 27695

4 Correspondence: Provimi R&T Centre, Lenneke Marelaan 2, B-1932 Sint Stevens Woluwe, Belgium (e-mail: theovankempen{at}yahoo.com).

The objective of this study was to compare three infrared spectroscopy techniques for routine evaluation of AA in animal meals. Animal meals (n = 54) with known AA contents were scanned with a near (NIRS), mid (FTIR), and Raman infrared spectrometer. For NIRS and Raman, samples were scanned "as is", whereas for FTIR, samples had to be finely ground before scanning to obtain reasonable spectra. Both FTIR and Raman data suffered from noise; for Raman, this prevented the development of calibrations. Using derivatized spectral data and a standardized outlier removal procedure, calibrations for nutritionally relevant AA could be developed that were equivalent for both NIRS and FTIR. The variation across AA tested explained (r2) by these calibrations was 70% for NIRS and 68 ± 3% for FTIR. Removing spectral data between 4,000 and 2,000 cm–1 from the FTIR data improved calibrations (P = 0.09) and explained an average of 77% of the variation with prediction errors lower than obtained with NIRS (P < 0.01). However, FTIR calibrations based on the entire or the shortened spectrum contained fewer samples than did NIRS calibrations (41 and 39 vs. 48, respectively; P < 0.01) because more samples were removed as outliers. In conclusion, Raman did not yield acceptable spectra for animal meals. For FTIR, sample preparation was more time-consuming because the samples required grinding before analysis. Using the entire mid-infrared range, FTIR calibrations were comparable to NIRS calibrations. Calibrations for FTIR were improved by eliminating wave numbers that exhibited more noise, resulting in prediction errors better than those for NIRS. Thus, FTIR has the potential to yield better calibrations for AA in animal meals than NIRS, but it requires greater care in sample preparation and scanning.

Key Words: Amino Acids • Animal Meal • Infrared • Quality Control